Artificial Intelligence-Driven Personalized Insulin Regimens:

Integration with Automated Delivery Devices, Continuous Glucose Monitoring and Predictive Algorithms

 

Waghamare Suresh*, Punam Nikam*, Sakshi Ambhore

Department of Pharmaceutics, Rashtriya College of Pharmacy, Hatnoor, Maharashtra, India - 431103.

*Corresponding Author E-mail: waghasuresh@gmail.com

 

ABSTRACT:

Diabetes management, particularly insulin dosing for individuals with type 1 and insulin-dependent type 2 diabetes, remains complex due to variability in glucose levels influenced by diet, physical activity, stress, and illness. Conventional insulin regimens often fail to maintain optimal glycemic control, increasing the risk of hypoglycemia and hyperglycemia. Recent advances in Artificial Intelligence (AI), Continuous Glucose Monitoring (CGM), and Automated Insulin Delivery (AID) systems have created new opportunities for personalized insulin therapy. This review highlights the role of AI-driven approaches in optimizing insulin regimens through machine learning, deep learning, reinforcement learning, and model predictive control algorithms. These technologies enable real-time adaptive insulin dosing, predictive glucose monitoring, and automated alerts for abnormal glucose fluctuations. Integration of AI with CGM and closed-loop insulin delivery systems has demonstrated improved Time in Range (TIR), reduced HbA1c levels, and lower hypoglycemia incidence compared to conventional therapy. The review also discusses challenges including algorithm transparency, data security, regulatory considerations, and population-specific adaptability. Emerging innovations such as digital twins, federated learning, and fully autonomous closed-loop systems may further advance precision diabetes management and improve patient outcomes.

 

KEYWORDS: Artificial intelligence, Personalized insulin therapy, Continuous glucose monitoring, Automated insulin delivery, Closed-loop systems, Machine learning, Predictive algorithms, Type 1 diabetes.

 

 


INTRODUCTION:

Diabetes mellitus is one of the biggest health challenges worldwide in the 21st century. According to the International Diabetes Federation (IDF) Diabetes Atlas 11th edition (2025), around 589 million adults aged 20 to 79 are living with diabetes globally. This represents 11.1% of the adult population.1 It is expected that this number will rise to 853 million by 2050. Diabetes causes over 3.4 million deaths each year and leads to high economic costs, surpassing USD 1 trillion in health spending.2 While Type 2 diabetes makes up most cases, Type 1 diabetes and insulin-requiring Type 2 diabetes create a heavy daily burden for patients due to their need for outside insulin therapy.3 Despite important developments in insulin formulations, traditional insulin regimens, such as multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) through pumps, often do not provide optimal glycemic control. Patients have to constantly adjust their insulin doses based on carbohydrate intake, physical activity, stress, illness, and other factors. This complicated decision-making can lead to significant fluctuations in glucose levels, with many experiencing both high and low blood sugar.4 Despite fear of hypoglycemia and related defensive behaviors, HbA1c levels tend to be suboptimal due to high risk aversion. Moreover, the subcutaneous route of insulin administration is physiological, skipping first-pass effect and contributing to peripheral hyperinsulinemia, weight gain, and lipodystrophy. As a result, fewer than half of patients meet target values, putting themselves at increased risk of micro-and macrovascular diabetic complications.5 Technological progress over the past two decades has substantially improved diabetes management. Continuous Glucose Monitoring (CGM) systems, first approved for professional use in the late 1990s and later for real-time personal use, replaced sporadic fingerstick measurements with near-continuous interstitial glucose data, trend arrows, and alerts. Insulin pumps evolved from basic continuous infusion devices in the 1970s to sophisticated systems with bolus calculators and temporary basal rates. The logical integration of these technologies led to sensor-augmented pumps and low-glucose suspend features, culminating in the first commercial hybrid closed-loop systems. The Medtronic MiniMed 670G, introduced in 2017, marked a pivotal milestone by automatically adjusting basal insulin every five minutes based on CGM readings. Subsequent systems (e.g., Medtronic 780G, Tandem Control-IQ, Omnipod 5) have further improved automation, achieving Time in Range (TIR 70–180 mg/dL) often exceeding 70% in clinical trials while reducing hypoglycemia.6,7 Nevertheless, current hybrid closed-loop systems remain “hybrid” because users must still announce meals, count carbohydrates accurately, and manage boluses. Performance varies considerably across individuals due to differences in insulin sensitivity, lifestyle, and physiology.8 This is where Artificial Intelligence (AI) and Machine Learning (ML) offer transformative potential. AI algorithms including supervised learning for glucose prediction, reinforcement learning for adaptive dosing, model predictive control (MPC), and deep neural networks can process vast multimodal datasets from CGM, insulin delivery records, physical activity trackers, and electronic health records to deliver personalized, real-time insulin recommendations that adapt dynamically to each patient’s unique profile.9 This review highlights the progress that has been made with regard to personalized algorithms for insulin, which can be used to create an AI-driven insulin protocol and their application to the automated delivery of insulin via a combination of AI, CGMs, and predictive models. This work looks into the use of AI/ML approaches, the techniques used to integrate all of these systems, the results gained by using them in terms of patient glycemic control and quality of life, the problems associated with implementing AI-based insulin protocols (such as generalization issues, lack of transparency in algorithms, cybersecurity risks, and regulatory hurdles), and potential future applications like closed-loop systems and digital twins.10

 

2. Fundamentals of Current Technologies:

There is no doubt that CGM technologies have revolutionized the way diabetes is managed through near-continuous monitoring of interstitial glucose levels, making it possible to rely less on conventional finger prick methods of blood glucose monitoring. Contemporary CGM technology incorporates a glucose sensor that is placed subcutaneously, a transmitter, and a receiving device or an app downloaded to a phone. CGM systems measure glucose levels at intervals of every 1–5 minutes, giving predictive alerts of hypo- and hyperglycemia.11 For, commercially available CGMs have excellent accuracy, with MARD being usually around 8% to 10%. Prominent CGM options are Dexcom G7 (10-day lifespan, MARD ~8.2%, factory calibrated), Abbott FreeStyle Libre 3/3+(14-day lifespan, smallest sensor footprint), Medtronic Guardian 4/Simplera series (tailored for pump compatibility), and Eversense 365 implantable sensor. The output data include clinically significant TIR 70–180mg/dL, TBR, TAR, and glucose variance parameters, which provide significantly better insights regarding patient's glycemic control than HbA1c measurements alone.( table 1) Nonetheless, despite the great value provided by CGM technology, some challenges persist, namely the 5- to 15-minute physiologic sensor lag time, temporary signal disruption, possible skin irritation at the insertion point, as well as limited availability depending on the country's healthcare infrastructure and reimbursement policy.12

 

Table 1. Comparison of Current Commercial Continuous Glucose Monitoring (CGM) Systems

Feature

Dexcom G7

FreeStyle Libre 3+

Medtronic Guardian 4

Eversense 365

Sensor Wear Duration

10 days

14 days

7 days

365 days

MARD (%)

~8.2

~9.0

~8.5–9.5

~8.5

Calibration Required

No

No

Optional

No

Real-time Display

Yes

Yes

Yes

Yes

Integration with AID

Excellent

Good

Excellent

Good

Approved Age Group

≥2 years

≥2 years

≥7 years

≥18 years

 

Systems for Automated Insulin Delivery (AID), also known as hybrid closed-loop systems or artificial pancreas technology, are the state-of-the-art devices for diabetes today. Such systems incorporate CGM measurements with an insulin pump and a control algorithm to deliver automated adjustment of basal insulin doses at intervals of 3–5minutes based on predicted glucose values. Major commercially available AID systems in the period are Medtronic MiniMed 780G with aggressive auto-correction boluses; Tandem t: slim X2 with Control-IQ technology; tubeless Insulet Omnipod 5; and Beta Bionics iLet Bionic Pancreas. Both clinical trials and pragmatic data have shown that AID leads to 10-25-percentage-point improvement in TIR relative to sensor-augmented pumps or MDI, reduces exposure to hypoglycemia, and decreases HbA1c. However, all existing systems retain a "hybrid" character because they require manual meal announcement and carb counting from the side of the patient, with additional intervention required in the case of exercise and illness.13–15

 

Traditional insulin management systems, like MDI and non-automated CSII methods, still remain prevalent although their inefficiencies have negative impacts on blood sugar levels control. Using these insulin treatment strategies requires great effort from patients since they must regularly check their glucose levels, dose their insulin carefully, and make adjustments based on the amount of carbohydrates ingested, exercising, stress level, hormone changes, illness, and other factors. These factors lead to frequent decision fatigue and diabetes burnout. Thus, glucose fluctuation becomes unavoidable, and the TIR of patients receiving these types of insulin therapy rarely exceeds 50%. The result is hyperglycemia episodes combined with hypoglycemia events. In an attempt to avoid hypoglycemia, patients often dose their insulin inadequately, leading to high HbA1c levels.16

 

Among additional issues are the variability of the rate of absorption of insulin into the body depending on its injection site, body temperature, physical activity, and changes in tissue permeability and the pharmacokinetics restrictions of rapid-acting insulin that demonstrate slow-onset action. Furthermore, even though state-of-the-art insulin pumps do not involve automation, their implementation still requires a lot of time spent manually calculating and programming basal rates and boluses. This is why most patients who use insulin cannot achieve glycemic goals due to lack of adequate education and technologies.17

 

3. Artificial Intelligence and Machine Learning Solutions:

The use of artificial intelligence and machine learning has become one of the key ways to cope with the issues associated with conventional and hybrid closed-loop insulin infusion. The usage of vast amounts of data on patient's characteristics makes it possible to create an insulin dosing strategy that will take into account all the individual variations. In this chapter, different approaches based on artificial intelligence and machine learning to personalizing insulin doses will be analyzed.18

 

3.1 Supervised Learning and Regression Models:

The supervised machine learning algorithms constitute the basis of many algorithms designed to forecast glucose levels and insulin delivery dosages.19 The input features are used to train the algorithms based on the historical data in order to determine the relationship between those input variables and the output variables, which could be either glucose level or the ideal insulin dosage.  Some regression approaches used include linear regression, support vector regression, random forest regression, gradient boosting methods such as XGBoost and Light GBM, and finally multilayer perceptron.20 These supervised methods perform exceptionally well in predicting the glucose level over the near future and suggesting the ideal insulin dosages because of their ability to incorporate factors like recent CGM reading, insulin-on-board, food intake, activity levels, and time of day. Research has shown that some of these methods have been capable of achieving a very low RMSE value below 20-30mg/dL within 30minutes. They are especially beneficial in predicting hypoglycemia and optimizing bolus dosage recommendations.21

 

3.2 Reinforcement Learning and Model Predictive Control (MPC):

Two major techniques for automated insulin delivery include reinforcement learning (RL) and model predictive control (MPC). MPC is a method of control based on optimization over a prediction horizon where future insulin rates are optimized using a cost function while adhering to safety constraints, such as insulin levels to avoid hypoglycemia. This approach involves constructing a model (mathematical/data-driven) of the dynamics of glucose-insulin and has been successfully applied in commercial and research-based hybrid closed-loop system designs.22

 

Reinforcement learning, on the other hand, views insulin delivery as a sequential decision-making process where an intelligent agent learns to make decisions in the face of environmental conditions in order to maximize certain rewards over time, which can be time in target glucose range. RL has proven particularly effective in handling more difficult situations like unexpected food intake and exercise. Techniques such as DDPG, PPO, and soft actor-critic from deep RL have been used in these applications. Hybrid RL-MPC approaches are becoming increasingly common.22

 

3.3 Deep Learning/Neural Networks:

Deep learning models, including recurrent neural networks (RNNs), LSTM, GRU, and CNN models, have shown their superiority in learning temporal relations in CGM time series data. In addition, they excel at performing multiple-step-ahead glucose prediction without the need for much hand-crafted feature engineering by using raw sensor data. (table 2) Transformers and attention methods have been proposed recently to concentrate on the most important patterns from the past. The ability of deep learning models to perform well under noisy, non-uniform, and multivariate data makes them better at forecasting under highly variable scenarios such as postprandial and nocturnal phases.23

 

Table 2. Summary of AI/ML Approaches Used in Personalized Insulin Delivery

Approach

Main Strengths

Limitations

Best Use Case

Supervised Learning

High interpretability, fast training

Needs frequent retraining

Glucose prediction, bolus advice

Reinforcement Learning (RL)

Adaptive, long-term optimization

Safety challenges

Fully closed-loop control

Model Predictive Control (MPC)

Strong safety constraints

Computationally intensive

Real-time basal adjustment

Deep Learning (LSTM/Transformers)

Excellent time-series modelling

Black-box, high data demand

Multimodal prediction

Hybrid/Ensemble Models

Best overall performance

Increased complexity

Clinical deployment

 

3.4 Ensemble Models:

A hybrid or ensemble system uses the strengths of more than one algorithm for improved effectiveness, accuracy, and robustness. Some examples of hybrid systems include stacking or voting systems using tree-based classifiers together with neural networks, as well as a combination of MPC-RIL or physics informed neural networks incorporating knowledge of the glucose-insulin system in deep learning algorithms. Hybrid approaches are generally better suited than traditional single system approaches since they allow integration of the interpretability offered by classical machine learning algorithms and the representational capacity provided by deep learning. Such systems are effective in situations involving high-fat meals, exercising, and sickness, where single approaches tend to underperform.24

 

 3.5 Data Sources and Feature Engineering:

Accurate AI-based insulin dosing is highly dependent on high-quality multimodal data sources. Primary data sources include frequent glucose monitoring data, insulin intake (basal and bolus), meal ingestion (carbohydrates, glycemic index), physical activity (heart rate, number of steps, accelerometry), sleep data, heart rate variability, and health record information (body weight, HbA1c, complications, medication). Feature engineering continues to play a vital role despite recent advancements in deep learning algorithms. Features like temporal data (hour of the day, day of the week), physiological information (rate of change, insulin, carbohydrates onboard), and context data (stress levels, menstrual cycle stage) greatly improve model performance. Data problems such as missing data, sensor noise, irregular sampling intervals, and personalization are major challenges in insulin dosing modeling. Methods like data augmentation, transfer learning, and federated learning are being used to tackle the issue of data scarcity and personalization.25

 

4. Integration of AI with CGM and Automated Delivery Devices:

The fusion of artificial intelligence algorithms with CGM-AID systems represents a major breakthrough towards more autonomous management of diabetes. Through the analysis of physiological data in real-time at a very high frequency, intelligent solutions offer the ability to forecast glucose levels, control insulin administration, and significantly reduce human interaction as opposed to legacy hybrid closed-loop systems. In this paper we discuss the underlying techniques that have enabled such fusion and analyze existing systems that incorporate AI solutions.26

 

4.1 Real-time Predictive Algorithms and Closed-Loop Control:

The real-time prediction algorithms are the core component of the implementation of artificial intelligence within the closed-loop system. The predictive algorithms operate on continuous glucose data streams and predict the level of blood sugar on short time horizons (15-60 minutes), then calculate the corresponding rates of insulin administration. Model Predictive Control (MPC) technique is commonly used since it involves optimal determination of future doses of insulin from the perspective of constrained optimization problems that take into account individual glucose-insulin dynamics.27

 

The latest developments involve the introduction of stochasticity into the algorithm or some form of uncertainty quantification to guarantee the safety of the closed-loop system at times of high variability of blood sugar levels. Reinforcement learning methods including deep reinforcement learning (e.g., Proximal Policy Optimization and actor-critic approaches) consider the insulin administration as a sequential decision-making task where an agent learns to maximize long-term rewards which reflect the duration of being in the target glucose range and penalize hypo- and hyperglycemia. Hybrid techniques combining the physiological relevance of MPC algorithms and adaptive learning of reinforcement learning are gaining popularity.22,28

 

4.2 Patient-Specific Personalization:

The ability to personalize according to the patient's characteristics provides a huge advantage of AI-based solutions compared to non-adaptive rule-based algorithms. Continuous model re-training on patient-specific data makes adjustments according to daily/long-term changes of insulin sensitivity due to illness, hormonal shifts, stress, physical activity, or changing body mass. Machine learning methods such as transfer learning, online learning, and clustering allow fast adjustment for each user based on the knowledge accumulated about patients with similar physiological characteristics.29,30

 

Several algorithms use ideas of digital twin to create personalized models that imitate dynamics of glucose-insulin in each patient and optimize dosing policies using offline algorithms. RL agents show particularly high effectiveness in personalized treatment as they interact with a patient's body and adapt their behavior accordingly. Clinical trials confirm better effectiveness of personalized adaptive algorithms compared to non-personalized ones, adding 5-15% more time spent within target range for glucose levels. Personalized solutions have been especially effective in treating children, adolescents, and pregnant women whose physiological characteristics demonstrate higher variability.31

 

4.3 Multimodal Data Fusion:

Multimodal data fusion substantially improves the reliability and precision of AI-based insulin delivery systems through the integration of multiple input channels aside from CGM glucose values. Current systems fuse CGM data together with insulin delivery records (basal and bolus), physiological parameters from wearables (heart rate, accelerometer measurements, heart rate variability, skin temperature), meal inputs (meal time, carbohydrate intake, glycemic index if known), sleep information, and even contextual features like location or calendar events. 32 State-of-the-art multimodal fusion approaches involve temporal attention strategies, hierarchical encoders, as well as biologically motivated dual-stream fusion architectures, where fast-changing and slowly changing data channels are processed individually prior to multimodal integration, thus improving prediction accuracy in more challenging conditions, for instance, post-exercise delayed hypoglycemia or fatty meal response. Uncertainty-based multimodal fusion methods are also being developed to increase safety by estimating uncertainty in predictions and adjusting insulin aggressiveness accordingly. Moreover, federated learning techniques are currently investigated to support collective learning among users without disclosing private data, thereby allowing generalized models without centralization of data.33

 

4.4 Prototype Systems and Case Studies:

A number of commercially available AID systems incorporate AI-enhanced functions as of 2026. For instance, Medtronic MiniMed 780G uses an advanced hybrid closed-loop technology featuring automatic correction bolus and machine learning. Tandem's Control-IQ algorithm (as well as its Control-IQ+ variant) applies a predictive approach for auto-correction boluses, among other expanded indications like pregnancy. Insulet's Omnipod 5 supports tubeless delivery with a smartphone application and further development into a fully closed-loop system, which has shown very encouraging outcomes in type 2 diabetes patients. Lastly, the Beta Bionics' iLet Bionic Pancreas relies exclusively on meal announcement (not on carbohydrate counting) and shows a strong outcome irrespective of the patient group.34 Some prototype and investigational systems aim at FCL operation without user announcements. In particular, Insulet is now running EVOLVE pivotal trial of a fully closed-loop system in type 2 diabetes while academia-industry collaborations explore various applications of multimodal reinforcement learning and transformer approaches in controllers. Clinical series and trials routinely show that TIR exceeds 70-80% without notable rates of hypoglycemia (<2-3% TBR) in both type 1 and certain type 2 diabetes populations. Nevertheless, there is still room for improvement in underrepresented subpopulations, physically active people, and during acute diseases.35

 

5. Clinical Evidence and Performance Evaluation:

The clinical study of AI-integrated automated insulin delivery (AID) systems has undergone explosive growth. The evidence for these has come from randomized controlled trials (RCTs), key studies, and increasingly from real-world experience. AI-AID systems have repeatedly been shown to improve on conventional therapy, sensor-augmented pumps, and multiple daily injections in varying populations and levels of pre-existing glycemic control.

 

5.1 Glycemic Outcomes (TIR, HbA1c, Hypoglycemia):

The use of AI in AID systems has resulted in considerable advances in glycemic outcomes. The increase in the median Time in Range (TIR, between 70 and 180 mg/dL) has been recorded at 10-25% when compared with the baseline or placebo groups. Thus, for example, the mean TIR value of Medtronic MiniMed 780G ranges from 74% to 78%, while the target-optimized TIR of Tandem Control-IQ and Insulet Omnipod 5 AID is 70-75%.36

 

 

The decrease in HbA1c concentration varies between 0.3 and 0.8%, with better outcomes for patients with higher HbA1c baseline concentration, for example, above 8.0%. The recent trials of the transition from MDI to tubeless AID among people suffering from type 1 diabetes resulted in an average decline of about 0.8% after 13 weeks. Moreover, Time Below Range (TBR <70mg/dL) was decreased to 1-3% – the value consistent with the international recommendations for TBR below 4% and less than 1% for TBR below 54 mg/dL. The TIR values in fully closed-loop and advanced hybrid systems, including those that employ reinforcement learning, exceed 75-80%.22

 

5.2 Safety, Usability, and Patient-Reported Outcomes:

The safety profile of AI-based AID systems appears to be positive, as the occurrence of severe hypoglycemia or diabetic ketoacidosis events is uncommon. Furthermore, no difference in the number of adverse events compared with the standard therapy has been shown in most studies. Concerning device-related side effects, like insertional reactions, connection problems, etc., no difference from conventional CGM and insulin pump devices was noted.37 High levels of usability have been observed in patients with an AI-based AID system, with the use of the automated function being higher than 90% among adherent participants. In particular, AI-based AID systems that allow using simplified devices (e.g., Beta Bionics iLet, which does not require any carbohydrate counting) demonstrate especially high user compliance. Regarding PRO measures, all patients exhibited improved diabetes distress, fear of hypoglycemia, sleep disturbances, and quality of life. Decreased mental and physical demands associated with decreased need for patient intervention contributed to low diabetes burnout scores. Still, alarm fatigue or frustration with occasional errors in dosages while ill or having high-fat meals were reported by some patients.38,39

 

5.3 Comparative Effectiveness:

Based on comparisons, advanced hybrid closed-loop systems appear superior to legacy hybrid and sensor-augmented pump technology. Head-to-head and cross-over trials have indicated that the Medtronic 780G provides better coverage against hyperglycemia (more time in range and less time above range), while specific Control-IQ settings can help with hypoglycemia prevention. Tube-based hybrid systems such as the Omnipod 5 provide similar glycemic results to tube-based systems while providing some potential benefits in usability and adherence among children and adults. Preliminary evidence supports the use of artificial intelligence in AID systems for treating type 2 diabetic patients who require insulin therapy. Significant decreases in HbA1c levels and time-in-range along with no increased hypoglycemia were observed. In small and medium sample sizes, digital twin technology and reinforcement learning proved slightly more effective than traditional hybrid loops in personalization. Thus, AI-based systems have produced substantial clinical gains in different age populations and diabetes types.40

 

 5.4 Limitations of Current Trials:

While showing promise, there are several limitations that prevent the current body of evidence from being generalizable. Pioneering clinical trials have used very short trial lengths (up to 6 months) and recruited very committed patients, lacking diversity in terms of ethnic minorities, socioeconomically disadvantaged people, and those with complex comorbidities and low adherence rates. Selection bias is evident in many studies due to self-selection by consistent and active users who share data.

 

Long-term follow-up data beyond a year are scarce, including information regarding glycemic improvement sustainability, incidence of microvascular complications, and cost-effectiveness. Algorithmic differences, variations in the precision of CGM data, various forms of insulin and patient behavior, as well as technical shortcomings such as lag time, connectivity, and the continuous requirement for meal announcement in hybrid models, continue to challenge the systems. Studies of totally closed-loop systems, pregnancy, in-hospital use, and developing countries are currently in progress.41

 

7. Future Directions and Emerging Trends:

There has been much progress made by researchers towards developing a completely autonomous, highly personal, and equitable solution using AI for insulin therapy. Future improvements in the areas of digital twins, federated learning, multimodal sensing, and precision medicine will overcome the challenges faced currently, reducing the day-to-day hassles of managing diabetes.

 

7.1 Digital Twins and Fully Closed-Loop Systems:

The development of digital twins may represent the next revolution in the delivery of next-generation insulin. Digital twins are highly personalized dynamic models of a specific individual's glucose-insulin interactions that incorporate real-time data through continuous glucose monitors, insulin delivery systems, and other relevant physiological signals. This allows for the testing of various combinations of insulin regimens, food intake, and exercise using the computer model prior to implementing these changes in reality. When coupled with reinforcement learning and/or physics-informed neural networks, digital twins enable the development of fully closed-loop (FCL) devices that require little to no patient intervention. The early iterations of such systems have already shown promising results by being able to accurately account for the presence of unannounced meals, physical exercise, stress, and sickness. Currently, there are many efforts underway to bring fully closed-loop systems into the market with FDA approval between 2027 and 2030. These systems would be especially beneficial for younger patients, elderly people, and individuals suffering from impaired awareness of hypoglycemia symptoms.42,43

 

7.2 Federated Learning and Privacy-Preserving AI:

However, there is still room for improvement when it comes to privacy and generalizability issues in AI-based diabetic innovations. Federated learning (FL) emerges as a promising approach through its ability to facilitate cooperation among thousands of devices while keeping private user data locally on either the user device or edge server. Model weights or gradients are only sent, thus minimizing the risk of leaks and resolving potential regulatory concerns such as GDPR and HIPAA. FL algorithms can further ensure more equitable access to healthcare due to their ability to train models on diverse samples across the globe, avoiding any need for pooling samples from well-off countries or areas. This trend combined with methods like differential privacy and homomorphic encryption makes federated approaches highly promising for achieving reliable generalization.44,45

 

7.3 Integration with Advanced Wearables and Precision Medicine:

Next-generation systems will be able to take into account the data of a larger ecosystem comprising wearables and biosensors. Apart from the current activity trackers, upcoming wearables such as sensors for heart rate variability, skin conductance (a proxy for stress), sweat glucose/lactate levels, voice biosensing for hypoglycemia detection, and circadian rhythms will become available. With multimodal data fusion of those parameters with CGM and insulin, more precise predictions and prevention of glucose excursions would be achievable. There is also a growing trend toward precision medicine approaches. The use of genetic profiles, microbiomes, insulin sensitivity clusters, and behavioral phenotyping will make it possible to develop personalized algorithms for subgroups. Thus, different predictive and preventive models can be developed depending on specific physiological processes in particular individuals: dawn phenomenon, menstrual cycles, or post-bariatric surgery physiology. Also, the integration of smart insulin pens, new long-acting insulins with once-per-week application, and glucagon infusion would enhance safety and flexibility.46 Among other trends, there are explainable AI interfaces that would provide patients and healthcare professionals with understandable explanations of how dosages are determined, integration with large language models for personalized guidance, cloud-edge computing to improve real-time performance with lower latency.

 

8. CONCLUSION:

The use of artificial intelligence technologies has proven itself to be an essential tool in transitioning insulin treatment from being predominantly manual and cumbersome towards being adaptive and patient-centric. Using AI algorithms that include but are not limited to supervised learning, reinforcement learning, model predictive control, as well as their combination, and by implementing continuous glucose monitoring and automating insulin delivery systems, there is evidence of the improvement in glycemic outcomes, such as Time in Range, decreased HbA1c levels, lower incidence of hypoglycemia, alongside decreasing the cognitive load for patients.

 

However, despite all the progress that has been made, many issues need to be addressed concerning model generalization, explainability, cybersecurity, safety, and accessibility of these solutions for different populations. Overcoming these barriers will help to achieve further advancements, such as using digital twins, federated learning, multimodal sensing, as well as a fully closed loop system. There is no question that the advent of artificial intelligence and automation in personalized insulin regimens holds great promise and can significantly improve the results and lives of diabetes sufferers. It is clear that further progress in this area requires collaborative efforts of healthcare practitioners, engineers, data scientists, regulators, as well as patients themselves.

 

9. CONSENT FOR PUBLICATION:

Not applicable. This article does not contain any person’s data in any form.

 

10. CONFLICT OF INTEREST:

The authors declare that they have no conflict of interest.

 

11. ACKNOWLEDGEMENT:

The authors sincerely acknowledge their respective institutions, including Rashtriya College of Pharmacy, Hatnoor; Nandkumar Shinde College of Pharmacy, Vaijapur; and Loknete Appasaheb Rajale College of Pharmacy, Adinathnagar, for providing academic support and research facilities. The authors are also grateful to faculty members, colleagues, and researchers in the fields of Artificial Intelligence, diabetes management, continuous glucose monitoring, and automated insulin delivery systems for their valuable scientific contributions, guidance, and encouragement during the preparation of this review manuscript.


12. REFERENCES:

1.      Chavan T, Waghamare S, Kokare S, Madake A. Advanced Treatment of Type 1 Diabetes with Teplizumab: Mechanism and Clinical Efficacy. Asian J Med Princ Clin Pract. 2025; 8:1–11. https://doi.org/10.9734/ajmpcp/2025/v8i1262.

2.      Mishra A, Waghamare S, Khanage SG. Acarbose-Loaded PLGA Microspheres: Efficient Encapsulation and Controlled Release. J Drug Deliv Ther. 2025; 15:30–40. https://doi.org/10.22270/jddt.v15i6.7165.

3.      Kostiuk M, Moore SL, Kramer ES, Gilens JF, Sarwal A, Saxon D, et al. Assessment and Intervention for Diabetes Distress in Primary Care Using Clinical and Technological Interventions: Protocol for a Single-Arm Pilot Trial. JMIR Res Protoc. 2025;14: e62916. https://doi.org/10.2196/62916.

4.      Chico A, Tundidor D, Jordana L, Saigi I, Maria MA, Corcoy R, et al. Changes in Insulin Requirements from the Onset of Continuous Subcutaneous Insulin Infusion (CSII) Until Optimization of Glycemic Control. J Diabetes Sci Technol. 2014; 8:371–7. https://doi.org/10.1177/1932296813520205.

5.      Mesa Díaz ÁM, Belmonte Lomas S, Rodríguez De Vera Gómez P, Llanes González MV, Mateo Rodríguez C, Hidalgo Sotelo L, et al. Fear of hypoglycemia is linked to poorer glycemic control and reduced quality of life in adults with type 1 diabetes. Front Endocrinol. 2025; 16:1563410. https://doi.org/10.3389/fendo.2025.1563410.

6.      Khan MS, Sivanantham S, Farouk L, Lakshmareddy DR, De Scolasticis S, Cresta E, et al. Real‐world glycaemic outcomes observed with the use of Medtronic 780G , Tandem Control‐ IQ and Omnipod 5 automated insulin delivery systems. Diabet Med. 2026; 43: e70251. https://doi.org/10.1111/dme.70251.

7.      Lai Y, Chen B, Chuang W, Jiang Y. Advances in continuous glucose monitoring and their impact on glycemic control in diabetes. J Diabetes Investig. 2026; 17:557–60. https://doi.org/10.1111/jdi.70273.

8.      Suresh AS, Pawar B. A Study of Factors of Lifestyle and its impact on Nutraceutical Consumption: India Perspective. Asian J Manag. 2018; 9:203. https://doi.org/10.5958/2321-5763.2018.00031.8.

9.      Huang W, Pang I, Bai J, Cui B, Qi X, Zhang S. Artificial Intelligence‐Enhanced, Closed‐Loop Wearable Systems Toward Next‐Generation Diabetes Management. Adv Intell Syst. 2025; 7:2400822. https://doi.org/10.1002/aisy.202400822.

10.   Wang X, Si J, Li Y, Tse P, Zhang G, Wang X, et al. Effectiveness and safety of AI-driven closed-loop systems in diabetes management: a systematic review and meta-analysis. Diabetol Metab Syndr. 2025; 17:238. https://doi.org/10.1186/s13098-025-01819-0.

11.   Afridi Z, Rauf SA, Ashraf SMN, Haque MA. Transformative Advances in Continuous Glucose Monitoring and the Impact of FDA Over‐the‐Counter Approval on Diabetes Care. Health Sci Rep. 2025; 8: e70747. https://doi.org/10.1002/hsr2.70747.

12.   Chawla P, Sowani A, Parikh R, Gupta A, Kesavadev J, Gokalani R, et al. Association between continuous glucose monitoring derived metrics and clinical parameters in Indian people living with type 2 diabetes. Prim Care Diabetes. 2025; 19:453–61. https://doi.org/10.1016/j.pcd.2025.06.004.

13.   Akcan T, Lee MY, Needleman L, Lal RA. Automated Insulin Delivery for Type 1 Diabetes: Present and Future. Diabetes Spectr. 2025; 38:217–27. https://doi.org/10.2337/dsi25-0003.

14.   Sherr JL, Heinemann L, Fleming GA, Bergenstal RM, Bruttomesso D, Hanaire H, et al. Automated insulin delivery: benefits, challenges, and recommendations. A Consensus Report of the Joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association. Diabetologia. 2023; 66:3–22. https://doi.org/10.1007/s00125-022-05744-z.

15.   Templer S. Closed-Loop Insulin Delivery Systems: Past, Present, and Future Directions. Front Endocrinol. 2022; 13:919942. https://doi.org/10.3389/fendo.2022.919942.

16.   Bellido V, Aguilera E, Cardona-Hernandez R, Diaz-Soto G, González Pérez De Villar N, Picón-César MJ, et al. Expert Recommendations for Using Time-in-Range and Other Continuous Glucose Monitoring Metrics to Achieve Patient-Centered Glycemic Control in People with Diabetes. J Diabetes Sci Technol. 2023; 17:1326–36. https://doi.org/10.1177/19322968221088601.

17.   Berget C, Sherr JL, DeSalvo DJ, Kingman RS, Stone SL, Brown SA, et al. Clinical Implementation of the Omnipod 5 Automated Insulin Delivery System: Key Considerations for Training and Onboarding People with Diabetes. Clin Diabetes. 2022; 40:168–84. https://doi.org/10.2337/cd21-0083.

18.   Parab R, Feeley JM, Valero M, Chadalawada L, Garcia G-GP, Kar SS, et al. Artificial Intelligence in Diabetes Care: Applications, Challenges, and Opportunities Ahead. Endocr Pract. 2025; 31:1615–25. https://doi.org/10.1016/j.eprac.2025.07.008.

19.   Waghamare S, Kudhekar A. Predictive Modeling of Physicochemical Properties Using Regression Algorithms. In: Waghamare S, Gaikwad A, Jahed S, Khanage S, editors. Artif. Intell. Preformulation Stud. Predict. Methods Mod. Pharm. Dev., Deep Science Publishing; 2026. https://doi.org/10.70593/978-93-7185-262-3_2.

20.   Guan Z, Li H, Liu R, Cai C, Liu Y, Li J, et al. Artificial intelligence in diabetes management: Advancements, opportunities, and challenges. Cell Rep Med. 2023; 4:101213. https://doi.org/10.1016/j.xcrm.2023.101213.

21.   Liu K, Li L, Ma Y, Jiang J, Liu Z, Ye Z, et al. Machine Learning Models for Blood Glucose Level Prediction in Patients with Diabetes Mellitus: Systematic Review and Network Meta-Analysis. JMIR Med Inform. 2023;11: e47833. https://doi.org/10.2196/47833.

22.   Yu X, Yang Z, Sun X, Liu H, Li H, Lu J, et al. Deep Reinforcement Learning for Automated Insulin Delivery Systems: Algorithms, Applications, and Prospects. AI. 2025; 6:87. https://doi.org/10.3390/ai6050087.

23.   Fera N, Procopio A, Zaffino P, Cutruzzolà A, Irace C, Cosentino C. Modeling strategies for CGM data: A scoping review of mechanistic, machine learning, and hybrid approaches in diabetes management. Comput Biol Med. 2026; 205:111601. https://doi.org/10.1016/j.compbiomed.2026.111601.

24.   Yang T, Sun J. A hybrid ensemble deep learning framework with novel metaheuristic optimization for scalable malicious website detection. Sci Rep. 2025; 15:44630. https://doi.org/10.1038/s41598-025-33695-z.

25.   Bai B, Liu X, Li H. Federated multimodal AI for precision-equitable diabetes care. Front Digit Health. 2026; 7:1678047. https://doi.org/10.3389/fdgth.2025.1678047.

26.   Waghamare S, Jahed S, Kudhekar A, Patil P, Nikam P. Foundations of Artificial Intelligence in Pharmaceutical Preformulation. In: Waghamare S, Gaikwad A, Jahed S, Khanage S, editors. Artif. Intell. Preformulation Stud. Predict. Methods Mod. Pharm. Dev., Deep Science Publishing; 2026. https://doi.org/10.70593/978-93-7185-262-3_1.

27.   Haidar A, Messier V, Legault L, Ladouceur M, Rabasa‐Lhoret R. Outpatient 60‐hour day‐and‐night glucose control with dual‐hormone artificial pancreas, single‐hormone artificial pancreas, or sensor‐augmented pump therapy in adults with type 1 diabetes: A n open‐label, randomised, crossover, controlled trial. Diabetes Obes Metab. 2017; 19:713–20. https://doi.org/10.1111/dom.12880.

28.   Warren M, Bergenstal RM, Hager M, Bashan E, Hodish I. A Scalable Application of Artificial Intelligence-Driven Insulin Titration Program to Transform Type 2 Diabetes Management. Diabetes Technol Ther. 2024; 26:556–65. https://doi.org/10.1089/dia.2024.0041.

29.   Deng G, Chengshi W. Intelligent technology-driven diabetes prevention and control: From informatization management to artificial intelligence. Sci Prog. 2026; 109:00368504261418899. https://doi.org/10.1177/00368504261418899.

30.   Hu Q, Xu J, Peng Y, Wang J, Huang G. The application of AI-based interventions in diabetes personalized management: a systematic review and meta-analysis. Diabetol Metab Syndr. 2026; 18:57. https://doi.org/10.1186/s13098-025-02079-8.

31.   Kovatchev BP, Colmegna P, Pavan J, Diaz Castañeda JL, Villa-Tamayo MF, Koravi CLK, et al. Human-machine co-adaptation to automated insulin delivery: a randomised clinical trial using digital twin technology. Npj Digit Med. 2025; 8:253. https://doi.org/10.1038/s41746-025-01679-y.

32.   Alsaadi GA, Alzanbaqi SF, Alharbi SA, Alahmadi LS, Alsaadi RY, Alsaedi DA, et al. Adaptive Multi-modal Fusion with Temporal Attention for Uncertainty-aware Closed-loop Insulin Delivery Control. J Adv Trends Med Res. 2025; 2:481–8. https://doi.org/10.4103/ATMR.ATMR_77_25.

33.   Jabbar A, Huang J, Jabbar MK, Ali A. Adaptive Multimodal Fusion in Vertical Federated Learning for Decentralized Glaucoma Screening. Brain Sci. 2025; 15:990. https://doi.org/10.3390/brainsci15090990.

34.   Niu F, Liu M, Yovanovich C, Vigersky RA, Shin JJ, McVean JJF. MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses. Diabetes Care. 2026; 49:419–25. https://doi.org/10.2337/dc25-2124.

35.   Ali D, Bilal AR, Arfin SMW, Sajid M, Qureshi S, Ahmed R, et al. Closed‐Loop Automated Insulin Delivery in Patients with Type 2 Diabetes: A Meta‐Analysis of Randomised Controlled Trials. Endocrinol Diabetes Metab. 2026;9:e70178. https://doi.org/10.1002/edm2.70178.

36.   Chico A, Moreno-Fernández J, Fernández-García D, Solá E. The Hybrid Closed-Loop System Tandem t: slim X2TM with Control-IQ Technology: Expert Recommendations for Better Management and Optimization. Diabetes Ther. 2024; 15:281–95. https://doi.org/10.1007/s13300-023-01486-2.

37.   Kudhekar A, Waghamare S, Kadag P. Smart Separation Techniques: AI-Based Optimization in the Formulation Process. In: Waghamare S, Gaikwad A, Jahed S, Khanage S, editors. Artif. Intell. Preformulation Stud. Predict. Methods Mod. Pharm. Dev., Deep Science Publishing; 2026. https://doi.org/10.70593/978-93-7185-262-3_4.

38.   Donaldson LE, Vogrin S, McAuley SA. Sensitivity of the Glycemia Risk Index to Effects of Automated Insulin Delivery Initiation. J Diabetes Sci Technol. 2024; 18:242–3. https://doi.org/10.1177/19322968231208957.

39.   Faulds ER, Rayan MN, Mlachak M, Dungan KM, Allen T, Patterson E. Artificial Intelligence Algorithms for Insulin Management and Hypoglycemia Prevention in Hospitalized Patients—A Scoping Review. Diabetology. 2026; 7:19. https://doi.org/10.3390/diabetology7010019.

40.   Hughes MS, Levy CJ. The Future of Automated Insulin Delivery Systems. Endocr Pract. 2025; 31:1162–70. https://doi.org/10.1016/j.eprac.2025.05.752.

41.   He Z, Tang X, Yang X, Guo Y, George TJ, Charness N, et al. Clinical Trial Generalizability Assessment in the Big Data Era: A Review. Clin Transl Sci. 2020; 13:675–84. https://doi.org/10.1111/cts.12764.

42.   Olawade DB, Owhonda RC, Alabi JO, Egbon E, Ayo Daniel RI, Bello OJ. Digital twin paradigm in diabetes prediction and management. Diabetes Res Clin Pract. 2026; 231:113075. https://doi.org/10.1016/j.diabres.2025.113075.

43.   Wang S, An M, Lin S, Kuy S, Li D. Artificial intelligence and digital twins: revolutionizing diabetes care for tomorrow. Intell Med 2025; 5:173–7. https://doi.org/10.1016/j.imed.2025.05.004.

44.   Ali A, Snášel V, Platoš J. Health-FedNet: A privacy-preserving federated learning framework for scalable and secure healthcare analytics. Results Eng. 2025; 27:106484. https://doi.org/10.1016/j.rineng.2025.106484.

45.   Jayalakshmi R, Tamilvizhi T. Privacy preservation in diabetic disease prediction using federated learning based on efficient cross stage recurrent model. Sci Rep. 2025; 15:37258. https://doi.org/10.1038/s41598-025-21229-6.

46.   Vo DK, Trinh KTL. Advances in Wearable Biosensors for Healthcare: Current Trends, Applications, and Future Perspectives. Biosensors. 2024; 14:560. https://doi.org/10.3390/bios14110560.

 

 

 

 

Received on 21.06.2026      Revised on 18.07.2026

Accepted on 13.08.2026      Published on 12.10.2026

Available online from October 21, 2026

Asian Journal of Pharmaceutical Analysis. 2026; 16(4):293-301.